UV Detector

Our product range includes a wide range of ecom - led20m uv detectors with display, ecom - ecd2800 uv-vis variable wavelength detector, ecom - led20m single uv-vis detector with display, ecom -led20m dual uv-vis detector with display, ecom - sedex 80 lt-elsd detector (hplc) sed80000 and ecom - sedex 90lt-elsd detector (hplc) sed90000.

ECOM - LED20M UV Detectors with display

Request Callback

₹ 370000 / Piece Get Latest Price

Product Brochure
Detector TypeUV
ApplicationChromatography
Output TypeLAN, RS232, USB
Spectral RangeUV
Area ClassificationSafe area
Power SupplyLine powered
Housing MaterialStainless steel
ApprovalIECEx
  • OLED display
  • Numerical and graphical view mode
  • Long lifetime of the LED light source
  • Low cell heating due to low power losses of the LEDs
  • USB-C powering and communication port
  • ECOMAC Basic software is free
  • Autozero function
  • Easy flow cell replacement
  • Small dimensions
  • ECOMAC SW -  sophisticated software for data acquisition and diagnostics

ECOM - ECD2800 UV-VIS Variable Wavelength Detector

Request Callback

₹ 620000 / Piece Get Latest Price

Product Brochure
Detector TypeUV DETECTOR
Applicationanalytical
Output TypeRS232
Spectral RangeUV
Power Supply100-240V 50/60Hz 100VA
Housing MaterialStainless steel
These detectors have continuously variable wavelength in the range of 190 - 800 nm and noise level is ± 5x10-6 AU.It is easy to operate; light intensities for reference and sample channels are available for detector diagnostics as well as information on lamp operating hours. The detector performs automatic  wavelength calibration after the lamp has been switched on. High standard deuterium lamp in a special socket enables easy exchange.

Output signal is available in both digital and analogue form. Detector could be controlled, programmed and used together with Clarity or ECOMAC software via RS232 or Ethernet interface.Cell could be easily removed from the front of the unit. Three selectable flow cells AC02AC05 and AC10 with optical path length 2.4, 5 and 10 mm. AC05 cell is included as component of the detector.

 

ECOM - LED20M Single UV-VIS Detector with display

Request Callback

₹ 350000 / Piece Get Latest Price

Product Brochure
Detector TypeUV Light-Emitting Diodes
Applicationchromatography techniques
Spectral RangeUV
Power Supply12-24 V DC
Housing MaterialStainless steel
  • OLED display
  • Numerical and graphical view mode
  • Long lifetime of the LED light source
  • Low cell heating due to low power losses of the LEDs
  • USB-C powering and communication port
  • ECOMAC Basic software is free
  • Autozero function
  • Easy flow cell replacement
  • Small dimensions
  • ECOMAC SW -  sophisticated software for data acquisition and diagnostics

ECOM -LED20M Dual UV-VIS Detector With Display

Request Callback

₹ 370000 / Piece Get Latest Price

Product Brochure
Detector TypeUV Light-Emitting Diodes
Applicationchromatography techniques
Spectral RangeUV dual UV
Power Supply12-24 V DC
Housing MaterialStainless steel
  • OLED display
  • Numerical and graphical view mode
  • Long lifetime of the LED light source
  • Low cell heating due to low power losses of the LEDs
  • USB-C powering and communication port
  • ECOMAC Basic software is free
  • Autozero function
  • Easy flow cell replacement
  • Small dimensions
  • ECOMAC SW -  sophisticated software for data acquisition and diagnostics

ECOM - SEDEX 80 LT-ELSD Detector (HPLC) SED80000

Request Callback

₹ 3720000 / Piece Get Latest Price

Product Brochure
Detector TypeELSD
Max Pressure3.5 bar
Wavelength470 nm
Light SourceBLUE LED
Flow Rangeless than 3ml min
Temperature ControlAmbient To 120 C
BrandOther Brand
ELSD detectors are univerzal detectors which measures sample particles after solvent evaporation by using scattered light. This kind of detection is independent of optical properties of sample in contrast to UV detection. Analyte must be lower volatile than solvent. It is possible to detect compounds without chromophores like: saccharides, lipids, polymers, non-derivatized fat acids and amino acids, oils, surface active compounds, small molecules and unknown compounds whitout information about their structure. Response of detector is depending on quantity and it is mean that detector can be used for quantitative analysis without calibration. It can be used in gradient applications and it not depend on temperature in contrast of RI detectors.

  • low evaporation temperature settings
  • choice of two nebulizers
  • easy validation and calibration
  • automated operation

ECOM - SEDEX 90LT-ELSD Detector (HPLC) SED90000

Request Callback

₹ 3580000 / Piece Get Latest Price

Product Brochure
Detector TypeELSD
Max Pressure3.5 bar
Wavelength470 nm
Light SourceBLUE LED
Flow Rangeless than 3 ml min
Temperature ControlAmbient To 120 C
BrandOther Brand
ELSD detectors are univerzal detectors which measures sample particles after solvent evaporation by using scattered light. This kind of detection is independent of optical properties of sample in contrast to UV detection. Analyte must be lower volatile than solvent. It is possible to detect compounds without chromophores like: saccharides, lipids, polymers, non-derivatized fat acids and amino acids, oils, surface active compounds, small molecules and unknown compounds whitout information about their structure. Response of detector is depending on quantity and it is mean that detector can be used for quantitative analysis without calibration. It can be used in gradient applications and it not depend on temperature in contrast of RI detectors.

  • low evaporation temperature settings
  • choice of two nebulizers
  • easy validation and calibration
  • automated operation

ECOM - TOYDAD 400 L Four Channel UV Detector

Request Callback

₹ 524000 / Piece Get Latest Price

Product Brochure
Detector TypeUV
ApplicationHPCL
Output TypeLAN & ANALOG
Spectral RangeUV
Power SupplyLine powered
Housing MaterialStainless steel
ApprovalIECEx
Wavelength range :- 200 - 400 nm (128 elements on CCD)
Number of channels :- 4

ECOM - ECD2600 UV Variable Wavelength Detector

Request Callback

₹ 560000 / Piece Get Latest Price

Product Brochure
Detector TypeUV Variable Wavelength Detector
Applicationanalytical
Output TypeRS232
Spectral RangeUV
Power Supply100-240V 50/60Hz 100VA

The units are suited for analytical applications.It is easy to operate; light intensities for reference and sample channels are available for detector diagnostics as well as information on lamp operating hours. The detector performs automatic wavelength calibration after the lamp has been switched on. High standard deuterium lamp in a special socket enables easy exchange.Output signal is available in both digital and analogue form. Detector could be controlled, programmed and used together with Clarity or ECOMAC software via RS232 or Ethernet interface.Cell could be easily removed from the front of the unit. Three selectable flow cells AC02AC05 and AC10 with optical path length 2.4, 5 and 10 mm. AC05 cell is included as component of the detector.

ECOM - ECD2800 UV-VIS Detector CE 190-800

Request Callback

₹ 726000 / Piece Get Latest Price

Product Brochure
Detector TypeUV-VIS Detector CE
Applicationcapillary electrophoresis
Output TypeRS232, Ethernet (LAN).
Spectral RangeUV
Power Supply100-240V 50/60Hz 100VA
Housing MaterialStainless steel

Newly developed cell enables easy installation of quartz capillaries and minimizes interference by ambient light as well as mechanical shocks. The light is brought into the cell using optical fiber, which is focused in the center of quartz capillary for electrophoresis.Detector is easy to operate, light intensities for reference and measuring channel are available for easy detector diagnostics as well as information about lamp operating hours. The detector performs automatic wavelength calibration after lamp start. High standard deuterium lamp in a special socket enables easy lamp exchange.Output signal is available in both digital and analogue form. Detector can be controlled, programmed and used together with Clarity or ECOMAC software via RS232 or Ethernet interface.

ECOM - ECD2600 UV-VIS Detector CE

Request Callback

₹ 600000 / Piece Get Latest Price

Product Brochure
Detector TypeUV-VIS Detector CE
Applicationcapillary electrophoresis
Output TypeRS232, Ethernet (LAN).
Spectral RangeUV
Power Supply100-240V 50/60Hz 100VA
Housing MaterialStainless steel
Newly developed cell enables easy installation of quartz capillaries and minimizes interference by ambient light as well as mechanical shocks. The light is brought into the cell using optical fiber, which is focused in the center of quartz capillary for electrophoresis.Detector is easy to operate, light intensities for reference and measuring channel are available for easy detector diagnostics as well as information about lamp operating hours. The detector performs automatic wavelength calibration after lamp start. High standard deuterium lamp in a special socket enables easy lamp exchange.Output signal is available in both digital and analogue form. Detector can be controlled, programmed and used together with Clarity or ECOMAC software via RS232 or Ethernet interface.

ECOM - ECD2800 UV-VIS EX Detector ( ADAEX00X )

Request Callback

₹ 726000 / Piece Get Latest Price

Product Brochure
Detector TypeUV-VIS EX Detector
Output TypeRS232
Spectral RangeUV
Power Supply100-240V 50/60Hz 100VA
Analytical UV-VIS detector with external cell. These detectors with wavelength in the range of  190 - 800 nm are derived from basic type ECD2600 / 2800. Cell is installed out of the unit and it is connected using fiber optic cables with SMA connectors.

Detector is easy to operate, light intensities for reference and measuring channel are available for easy detector diagnostics as well as information about lamp operating hours. The detector performs automatic wavelength calibration after lamp start. High standard deuterium lamp in a special socket enables easy lamp exchange.

Output signal is available in both digital and analogue form. Detector can be controlled, programmed and used together with Clarity or ECOMAC software via RS232 or Ethernet interface. 

ECOM - ECD2600 UV-VIS EX Detector ( ADBEX00X )

Request Callback

₹ 600000 / Piece Get Latest Price

Product Brochure
Detector TypeUV-VIS EX Detector
Output TypeRS232
Spectral RangeUV
Power Supply100-240V 50/60Hz 100VA
Analytical UV-VIS detector with external cell. These detectors with wavelength in the range of  190 - 800 nm are derived from basic type ECD2600 / 2800. Cell is installed out of the unit and it is connected using fiber optic cables with SMA connectors.Detector is easy to operate, light intensities for reference and measuring channel are available for easy detector diagnostics as well as information about lamp operating hours. The detector performs automatic wavelength calibration after lamp start. High standard deuterium lamp in a special socket enables easy lamp exchange.
Output signal is available in both digital and analogue form. Detector can be controlled, programmed and used together with Clarity or ECOMAC software via RS232 or Ethernet interface. 

ECOM - Fluorescence Detector RF-20A

Request Callback

₹ 3192600 / Piece Get Latest Price

Number of Channels1
Power Supply220-240 v
The fluorescence detector with very high sensitivity, is easily maintainable and has got several validation and support functions.
It can be used in many applications in the framework of 200 to 650 nm wavelength ranges – from conventional analysis to high-performance analysis.
The detector´s noise ratio is 1200 for the water-Raman band, and the fluorescence detector is suitable for trace analysis.
Also, the xenon lamp and the flow cell are easily accessible and allow easy handling and maintenance of the device by the user, which minimizes downtime. The lamp life is 2000 hours. A lamp replacement doesn´t require adjustments.  

ECOM - pH Flow Cell PEEK ( PHC18000 )

Request Callback

₹ 70000 / Piece Get Latest Price

The internal shapes and overall internal concept inside the pH cell are designed to maintain a smooth flow of liquid to prevent cross-contamination, poor flushing of the cell, or a build-up of impurities. A 3.1 inspection certificate can be delivered with the cell. The cell is compatible with the pH probe S450CD (flat-bottom). Seals used: TEFLON rings

Accessories: As an accessory for the pH cell, it is possible to purchase a blanking plug made of PEEK, part number TCPH0010. It serves as a cap for the pH cell so that the cell can be cleaned during flow when the cell is used without the pH sensor.