HPLC System

We are a leading Retail Trader of ecom - ecs03 isocratic analytical hplc system, ecom - ecs05 quaternary gradient autosampler pda analytical hplc system, ecs01 quaternary gradient analytical hplc system, ecs02 quaternary gradient analytical hplc system and ecs04 quaternary gradient autosampler analytical hplc system from Mumbai, India.

ECOM - ECS03 Isocratic Analytical HPLC System

Request Callback

₹ 1422000 / Piece Get Latest Price

Product Brochure
System TypeAnalytical HPLC
Pump TypeBinary
Max Pressure400 bar
Detector TypeUV
AutosamplerIncluded
Flow Range0.001 to 1 mL/min
Column OvenIncluded
Number Of Channels1 channel
BrandEcom
Product Part NumberAXA0300X
Model NumberECS03
Voltage (V AC)240
Frequency50 Hz
Set ContentUV-VIS Detector, Analytical Pump and Box For Mobile Phase Bottles
ECD2600 UV-VIS DetectorADB0000X
ECP2010 Analytical HPLC pumpACA0000X
ECB2006 Box for MOBILE Phase BottlesABC0000X
Clarity – Station for 1 instrumentAP000C50
Clarity module for HPLC controAP000A24
  • Communication of all units is through RS232 or Ethernet(LAN). An additional PC A/D converter card is not required for this system.
  • The system contains a manual injector and Clarity software. All units are supported in Clarity software from installation.
  • A wireless mouse and keyboard set (P/N: EPC-0028), PC (P/N: EPC-0026) and a computer monitor (P/N: EPC-0027) can be purchased with the system.
  • Main Parts-ECD2600 UV-VIS Detector
  • Detector with a continuously variable wavelength in the range of 190-600 nm and a noise level ±3·10-6 AU. The unit offers high-speed sampling up to 100 Hz and wavelength autocalibration. AC 05 analytical cell is included.
  •  ECP2010 Analytical Hplc Pump
  • This isocratic pump works with Gradient Box ECB2004B as a quaternary gradient pump. The flow rate range is 0.02-10.00 ml/min and the pressure limit at 40 MPa. Unit software includes a new learning algorithm for pulsation suppression and many testing and diagnostic functions.
  •  ECB2006 Box For Mobile Phase Bottles
  • The box is suited for secure mobile phase bottles installation onto isocratic systems
  •  Clarity Chromatography Software
  • This system is fully controlled by Clarity chromatography software, which is also a part of delivery. Clarity software complies with CFR21GLP requirements.

ECOM - ECS05 Quaternary Gradient Autosampler PDA Analytical HPLC System

Request Callback

₹ 950000 / Piece Get Latest Price

Product Brochure
System typeAnalytical HPLC
Pump typeBinary pump
Max pressure400 bar
Flow rate0.001 to 5 mL/min
Detector typeUV detector
AutosamplerYes
Frequency50 Hz
Voltage240 VAC
Model NumberECS05
Product Part NumberASA0500X
Product BrandEcom
Set ContentUV-VIS PDA Detector, Column Oven, Analytical Pump, Gradient Box and Autosampler
  • Highly effective HPLC system containing a UV-VIS detector, a column oven, an analytical pump, a gradient box, and an autosampler.
  • Detector with eight channels in range of 200-800 nm and very low noise level offers also high-speed scanning with speed up to 100 Hz. Communication of units is through RS232 or Ethernet(LAN). An additional PC A/D converter card is not required for this system. The system contains autosampler and Clarity software. All units are supported in Clarity software from installation. 
  • A wireless mouse and keyboard set (P/N: EPC-0028), PC (P/N: EPC-0026) and a computer monitor (P/N: EPC-0027) can be purchased with the system.
Main parts-ECDA2800 UV-VIS Pda Detector
  • Analytical Diode Array Detector measures at eight wavelengths simultaneously or performs a full scan with a speed up to 100 Hz. 3D support in Clarity SW. Noise level ±5x10-6 AU. Four analog outputs. Two special mathematical channels are available. AD 05 analytical cell is included.
  

ECS01 Quaternary Gradient Analytical HPLC System

Request Callback

₹ 2325000 / Piece Get Latest Price

Product Brochure
System typeAnalytical HPLC
Pump typeBinary pump
Max pressure400 bar
Model Name/NumberECS01 Gradient Analytical system
Usage/ApplicationLaboratory Use
Flow rate0.001 to 5 mL/min
Display Inch5 Inch
Detector typeUV detector
AutosamplerYes
Frequency50 Hz
Voltage240 V AC
BrandEcom
Part NumberASA0100X
Set ContentUV-VIS Detector, Column Oven, Analytical Pump And Gradient Box
  • Communication of all units is through RS232 or Ethernet (LAN). An additional PC A/D converter card is not required for this system.
  • The system contains a manual injector and  Clarity software. All units are supported in Clarity software from installation.
  • A wireless mouse, a keyboard set (P/N: EPC-0028), a PC (P/N: EPC-0026), and a computer monitor (P/N: EPC-0027) can be purchased with the system.
  • Main parts
  • ECD2800 UV-VIS Detector
  • Detector with a continuously variable wavelength in the range of 190-800 nm and a noise level ±3·10-6 AU. The unit offers high-speed sampling up to 100 Hz and wavelength autocalibration. AC 05 analytical cell is included.
  • ECO2080 Column Oven With Heating And Cooling
  • The Peltier heating/cooling column oven with a big compartment room can accommodate up to 3 columns with lengths up to 25 cm. Overheating-Security-Fuse prevents the destruction of temperature-sensitive columns. The temperature range is 0-80 °C.
  • ECP2010 Analytical HPLC Pump
  • This isocratic pump works with Gradient Box ECB2004B as a quaternary gradient pump. The flow rate range is 0.02-10.00 ml/min and the pressure limit at 40 MPa. Unit software includes a new learning algorithm for pulsation suppression and many testing and diagnostic functions.
  • ECB2004B Gradient Box With Degasser
  • The box is suited for handling liquids in ECOM gradient systems.
  • It accommodates a container for solvent bottles, a built-in high-efficiency vacuum degasser, and a four-way gradient valve. Up to four solvent lines may be degassed simultaneously by one unit. A four-way gradient valve is controlled from the pump ECP2010.
  •  Clarity Chromatoghaphy Software
  • This system is fully controlled by Clarity Chromatography software, which is also a part of delivery. Clarity software complies with CFR21GLP requirements

ECS02 Quaternary Gradient Analytical HPLC System

Request Callback

₹ 2089500 / Piece Get Latest Price

Product Brochure
System typeAnalytical HPLC
Pump typeBinary pump
Max pressure400 bar
Model Name/NumberECS02 Gradient Analytical system
Usage/ApplicationLaboratory Use
Flow rate0.001 to 5 mL/min
Display Inch5 Inch
Detector typeUV detector
AutosamplerYes
Dimension405 x 490 x 525 mm (W x D x H)
Frequency50 Hz
Voltage240 VAC
BrandEcom
Part NumberASA0200X
Set ContentUV-VIS Detector, Column Oven, Analytical Pump And Gradient Box
ECD2600 UV-VIS DetectorADB0000X
ECP2010 Analytical HPLC pumpACA0000X
ECO2099 Column Oven with heatingAOB0000X
  • Highly effective HPLC system containing UV-VIS detector, column oven, analytical pump, and gradient box. Detector with continuously variable wavelength 190-600 nm and very low noise level offers high-speed sampling up to 100 Hz.
  • Communication of all units is through RS232 or Ethernet(LAN). An additional PC A/D converter card is not required for this system.
  • The system contains a manual injector and the Clarity System contains a manual injector and Clarity software. All units are supported in Clarity software from installation.
  • A wireless mouse and keyboard set (P/N: EPC-0028), PC (P/N: EPC-0026) and a computer monitor (P/N: EPC-0027) can be purchased with the system.
Main parts-ECD2600 UV-VIS Detector
  • Detector with a continuously variable wavelength in the range of 190-600 nm and a noise level ±3·10-6 AU. The unit offers high-speed sampling up to 100 Hz and wavelength autocalibration. AC 05 analytical cell is included.
 ECO2099 Column Oven With Heating And Cooling
  • This column oven allows temperature stabilization above ambient temperature. A big compartment room
  • can accommodate up to 3 columns with lengths up to 25 cm. Overheating- Security-Fuse prevents the destruction of temperature-sensitive columns. The temperature range is ambient temperature +5°- 99 °C.
 ECP2010 Analytical HPLC Pump
  • This isocratic pump works with Gradient Box ECB2004B as a quaternary gradient pump. The flow rate range is 0.02-10.00 ml/min and the pressure limit at 40 MPa. Unit software includes a new learning algorithm for pulsation suppression and many testing and diagnostic functions.
 ECB2004B Gradient Box With Degasser
  • The box is suited for handling liquids in ECOM gradient systems. It accommodates a container for solvent bottles, a built-in high-efficiency vacuum degasser, and a four-way gradient valve. Up to four solvent lines may be degassed simultaneously by one unit. A four-way gradient valve is controlled from the pump ECP2010.
 Clarity Chromatoghaphy Software
  • This system is fully controlled by Clarity Chromatography software, which is also a part of delivery. Clarity software complies with CFR21GLP requirements.

ECS04 Quaternary Gradient Autosampler Analytical HPLC System

Request Callback

₹ 900240 / Piece Get Latest Price

Product Brochure
System TypeAnalytical HPLC
Max Pressure400 bar
Detector TypeUV
Flow Range0.001 to 1 mL/min
Number Of Channels1 channel
Model NumberECS04
Product Part NumberASA0400X
Product BrandEcom
Flow Rate (ml/min)10
Max. Pressure40 Mpa/ 5802 psi
Number Of Solvents4
TypeHPLC Analytical Gradient System
Set ContentUV-VIS PDA Detector, Column Oven, Analytical Pump, Gradient Box and Autosampler
Pump TypeBinary
  • Highly effective HPLC system containing a UV-VIS detector, a column oven, an analytical pump, a gradient box, and an autosampler.
  • Detector with continuously variable wavelength 190-800 nm and very low noise level offers high-speed sampling up to 100 Hz.
  • Communication of units is through RS232 or Ethernet(LAN). An additional PC A/D converter card is not required for this system. The system contains autosampler and Clarity software. All units are supported in Clarity software from installation.
  • A wireless mouse and keyboard set (P/N: EPC-0028), PC (P/N: EPC-0026) and a computer monitor (P/N: EPC-0027) can be purchased with the system.

Main parts

ECD2800 UV-VIS Detector

  • Detector with a continuously variable wavelength in the range of 190-800  nm and a noise level ±3·10-6 AU. The unit offers high-speed sampling up to 100 Hz and wavelength autocalibration. AC 05 analytical cell is included.

ECO2080 Column Oven With Heating And Cooling

  • This column oven allows precise temperature stabilization in the range of 0-80°C. A big compartment room can accommodate up to 3 columns with lengths up to 25 cm. Peltier technology offers the possibility of heating and cooling independently from room temperature.

ECP2010 Analytical HPLC Pump

  • This isocratic pump works with Gradient Box ECB2004B as a quaternary gradient pump. The flow rate range is 0.02-10.00 ml/min and the pressure limit at 40 MPa. Unit software includes a new learning algorithm for pulsation suppression and many testing and diagnostic functions.

ECB2004B Radient Box With Degasser

  • The box is suited for handling liquids in ECOM gradient systems. It accommodates a container for solvent

 

X

Contact Us

Abhishek Pirdhankar (CEO)
APP
First Floor,B-11, Sai,Krupa, Chawl M.G.Road Charkop,Village, Kandivali-West, Mumbai - 400067, Maharashtra, India

Get Directions
Send Email
Share: